Boonton 4500B Peak Power Meter Bedienungsanleitung Seite 239

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 372
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 238
Boonton 4500B RF Peak Power Analyzer
Remote Operation
5-39
FETCh:MARKer:MAXimum?
Description: For the specified channel and marker, return the maximum power or voltage at the marker. The
units are the same as the specified channel.
Syntax: FETCh[1|2|3|4|6|7]:MARKer[1|2]:MAXimum?
Returns: CC, maximum power or voltage at marker
Where CC is the measurement condition code.
Valid Modes: Pulse and Modulated.
FETCh:MARKer:MINimum?
Description: For the specified channel and marker, return the minimum power or voltage at the marker. The
units will be the same as the specified channel.
Syntax: FETCh[1|2|3|4|6|7]:MARKer[1|2]:MINimum?
Returns: CC, minimum power or voltage at marker
Where CC is the measurement condition code.
Valid Modes: Pulse and Modulated.
FETCh:MARKer:RATio?
Description: For the specified channel return the ratio of MK1 to MK2. The units will be dB for logarithmic
units or percent for linear units..
Syntax: FETCh[1|2|3|4|5|6|7]:Marker:RATio?
Returns: CC, MK1/MK2
Where CC is the measurement condition code.
Valid Modes: All
FETCh:MARKer:RDELTa?
Description: For the specified channel return the difference between MK2 and MK1. The units will be the same
as marker units.
Syntax: FETCh[1|2|3|4|5|6|7]:MARKer:RDELTa?
Returns: CC, (MK2-MK1)
Where CC is the measurement condition code.
Valid Modes: All
Seitenansicht 238
1 2 ... 234 235 236 237 238 239 240 241 242 243 244 ... 371 372

Kommentare zu diesen Handbüchern

Keine Kommentare